A factory sets a defect limit of 2%, records 7%, identifies poor machine calibration and repairs the equipment. Identify the control steps illustrated and explain why merely recording 7% is insufficient.
Answer – The steps are setting standards, measuring performance, comparing results, analysing deviations and corrective action. Measurement alone only reveals the result. Control must identify the cause and correct it, then check whether the defect rate improves.